Product Specifications
- Operating current: 105-130 VAC (50/60Hz)
- Operating temperature: -40°C to 60°C
- Capacity: 1500 W
- Made in Mexico.
Instructions
Mounting: When placing the unit in the tripolar receptacle, insert the three terminals, press down while turning the control from left to right, the maximum reaction to the sensitivity of the spectrum is obtained when the indicator (N) is oriented towards the north.
The lamp will turn on when the photocontrol is installed. If installed during the day, it will turn it OFF after a short delay. To turn the lamp back on after installation, cover the photo control. Power-up will occur after the delay period (5-15 sec.). The length of the delay varies according to the ambient light.
Calibration: The photocells are already adjusted by default at normal light levels. If you require other levels, ask the factory.
Warning: Thi photocell must be exposed during 2 or 3 days after unpacking before it reacts to the light level for which it was calibrated.